Mitsubishi FX2N-232-BD - User Manual

Mitsubishi FX2N-232-BD
728 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
USER'S MANUAL - Data Communication Edition
FX SERIES PROGRAMMABLE CONTROLLERS
N:N Network
Parallel Link
Computer Link
Inverter Communication
Non-Protocol Communication
Programming Communication
Remote Maintenance
FX
3U
Series
Inverter Communication
(F700/A700/E700/D700 Series)
FX
3G
Series
EFX3UƒVƒŠ[ƒY
Additional Product Support
Version
FX
3U
-232-BD
RS-232C Interface
FX
2N
-232-BD
FX
1N
-232-BD
FX
3U
-232ADP(-MB)
FX-232ADP
FX
2NC
-232ADP
FX
0N
-232ADP
FX
2N
-232IF
RS-485 Interface
FX
3U
-485-BD
FX
2N
-485-BD
FX
1N
-485-BD
FX
3U
-485ADP(-MB)
FX-485ADP
FX
2NC
-485ADP
FX
0N
-485ADP
RS-485/232C Converter
FX-485PC-IF
FX
3U
-422-BD
FX
1N
-422-BD
FX
2N
-422-BD
RS-422 Interface
USB Interface
FX
3U
-USB-BD
FX
3G
-232-BD
FX
3G
-485-BD
FX
3G
-422-BD

Table of Contents

Questions and Answers

  • J
    Jasmine MendozaAug 14, 2025
    Should I set parameters for the N:N Network on my Mitsubishi FX2N-232-BD?
    • T
      Taylor BrownAug 14, 2025
      No, you should not set parameters for the N:N Network. Verify that the communication settings using parameters are suitable for use.
  • S
    smithstephenAug 17, 2025
    What to do if communication is not possible with Mitsubishi FX2N-232-BD Controller because of incorrect wiring?
    • N
      Nancy FoxAug 17, 2025
      If communication is failing, it might be due to incorrect wiring. Ensure that all communication equipment is wired correctly.
  • M
    michaelkimAug 21, 2025
    What to do if communication is not possible with Mitsubishi Controller when a communication port is set twice?
    • A
      adamgilbertAug 21, 2025
      If communication fails, it could be because a communication port is set more than once. Verify that the communication format (D8120, D8400 and D8420) is set correctly.
  • O
    Olivia EvansAug 25, 2025
    What to do if communication is not possible with Mitsubishi FX2N-232-BD Controller when using RS and RS2 instructions?
    • S
      Shawn ClarkAug 26, 2025
      If communication is failing, check that the RS and RS2 instructions are not being used for the same channel.
  • C
    Cindy CampbellAug 29, 2025
    What to do if communication is not possible with Mitsubishi FX2N-232-BD when using the RS instruction?
    • S
      Scott FrancisAug 29, 2025
      If communication is not working, verify that the RS instruction is not used in the program.
  • J
    Jason GomezSep 1, 2025
    What to do if communication is not possible with Mitsubishi FX2N-232-BD when using EXTR instruction?
    • T
      Travis RomanSep 2, 2025
      If communication isn't working, ensure that the EXTR instruction is not used in the program.
  • G
    Grant SandovalSep 4, 2025
    What to do if communication is not possible with Mitsubishi FX2N-232-BD when using VRRD and VRSC instructions?
    • C
      Christian LeeSep 5, 2025
      If communication isn't working, verify that the VRRD and VRSC instructions are not used in the program.
  • B
    Betty RobinsonSep 9, 2025
    What to do if communication is not possible with Mitsubishi Controller when using IVCK, IVDR, IVRD, IVWR, and IVBWR instructions?
    • T
      tmartinezSep 9, 2025
      If communication is failing, verify that the IVCK, IVDR, IVRD, IVWR and IVBWR instructions are not being used for the same channel.

Summary

FX Series Programmable Controllers Users Manual

Data Communication Edition

User's manual covering data communication editions, serial communication, and applicable FX PLCs.

Safety Precautions

1. DESIGN PRECAUTIONS

Precautions for designing safe systems, including emergency stops and protection circuits.

2. WIRING PRECAUTIONS

Precautions for wiring, including electrical shock prevention and noise disturbance.

3. STARTUP AND MAINTENANCE PRECAUTIONS

Precautions for startup, cleaning, and maintenance of the PLC.

Programming Communication

5. Communication Setting (Initialization) in FX Programmable Controller

Explains communication setting methods and initialization procedures using parameters.

Remote Maintenance

5. How to Setup Modems on the PLC Side

Details modem setup methods using GX Developer and FXGP/WIN on the PLC side.

6. How to Setup Modems on the PC Side for Remote Access

Explains modem setup on the PC side, including AT command registration and telephone directory.

8. Troubleshooting

Covers troubleshooting for PLC version, communication status, installation, and modems.

Mitsubishi FX2N-232-BD Specifications

General IconGeneral
ModelFX2N-232-BD
Communication ProtocolRS-232C
Number of Channels1
Data Length7 or 8 bits
Stop Bit1 or 2 bits
Applicable PLCFX2N Series
Weight0.1 kg
CompatibilityFX2N Series PLC
ParityEven, Odd, or None
Power Supply5V DC (from PLC)
Current Consumption60 mA
TypeRS-232C Communication Board