EasyManuals Logo

Mitsubishi FX2N-232-BD User Manual

Mitsubishi FX2N-232-BD
728 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #281 background imageLoading...
Page #281 background image
D-63
FX Series PLC User's Manual - Data Communication Edition
Computer Link
7 Commands
7.6 QW Command [Writes Device Memory in 1-Word Units]
A
Common Items
B
N:N Network
C
Parallel Link
D
Computer Link
E
Inverter
Communication
F
Non-Protocol
Communication
(RS/RS2 Instruction)
G
Non-Protocol
Communication
(FX
2N
-232IF)
H
Programming
Communication
I
Remote
Maintenance
Apx.
Discontinued
models
7.6 QW Command [Writes Device Memory in 1-Word Units]
This section explains the control procedure specification method and shows a specification examples when
the word device memory is written all at once or when the bit device memory is written (in 16-point units) all at
once.
1. Specification method
The specification method in the control procedure format 1 is shown below:
1) This command is available only in FX
3G, FX3U and FX3UC PLCs.
2) Specify the device point range while satisfying the following conditions:
-1 Number of device points 64 (10 in case of bit devices)
- Head device number + Number of device points ("Number of devices × 16" in case of bit devices) -1
Maximum device number
- When 32-bit devices (CN00200 to CN00255) are written, one device point is handled as two word data.
Accordingly, up to 32 device points can be specified.
3) Express the station number, PLC number, number of device points and sum check code in hexadecimal.
2. Specification examples (For FX3U and FX3UC PLCs)
Example 1: When writing data to thirty-two devices from M640 to M671 in the PLC whose station number is
5 (while the message waiting time is set to 0 ms)
Computer side
PLC side
E
N
Q
QW
Head device
(7 characters)
A
C
K
Character area C
One device uses 4 characters. Four digits
(hexadecimal) express one data word.
Number of device points
(2 characters (hexadecimal)
Batch write command
(unit: word)
Written device range
specification
Data on
specified
number of
device points
Station
No.
PLC No.
Sum check
code
Message
wait time
Station
No.
PLC No.
A
C
K
0 5 F F
0 2 6 4
E
N
Q
0 5 F F Q W 0
This range is regarded as the
sum check target.
35
H
30
H
46
H
46
H
57
H
51
H
30
H
4D
H
36
H
32
H
34
H
36
H
05
H
35
H
30
H
46
H
46
H
06
H
0 0 1 0111001000 0100100110110 0 1111 1
M
6
5
6
23 69BA74
M
6
5
7
M
6
6
3
M
6
6
4
M
6
7
1
M
6
4
0
M
6
4
1
M
6
4
7
M
6
4
8
M
6
5
6
Computer side
PLC side
M0 0 0 6
34
H
40
32
H
41
H
37
H
34
H
33
H
2347A
42
H
B
39
H
96
36
H
30
H
30
H
30
H
30
H
30
H

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi FX2N-232-BD and is the answer not in the manual?

Mitsubishi FX2N-232-BD Specifications

General IconGeneral
BrandMitsubishi
ModelFX2N-232-BD
CategoryController
LanguageEnglish

Related product manuals