EasyManuals Logo

Mitsubishi FX2N-232-BD User Manual

Mitsubishi FX2N-232-BD
728 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #85 background imageLoading...
Page #85 background image
A-57
FX Series PLC User's Manual - Data Communication Edition
Common Items
3 Outline of Communication Setting in the FX Series
3.2 Communication Setting Using Parameter Method (GX Developer)
A
Common Items
B
N:N Network
C
Parallel Link
D
Computer Link
E
Inverter
Communication
F
Non-Protocol
Communication
(RS/RS2 Instruction)
G
Non-Protocol
Communication
(FX
2N
-232IF)
H
Programming
Communication
I
Remote
Maintenance
Apx.
Discontinued
models
3.2.2 Correspondence between parameter setting and each communication type
The table below shows the communication types and set items which can be set using parameters:
*1. Only available for FX
3G PLC.
Set item Contents
CC-Link network
N:N Network
Parallel link
Computer link
Inverter communication
Non-protocol communication (RS/RS2 instruction)
Non-protocol communication (FX2N-232IF)
Short mail sending
Internet mail sending
CC-Link/LT network
AS-i system
Programming communication
Remote maintenance
Remarks
Protocol
Non-protocol
communication
This communication is not executed in this setting.
This communication is not executed in this setting.
This communication is not executed in this setting.

This communication is not executed in this setting.
This communication is not executed in this setting.
This communication is not executed in this setting.
This communication is not executed in this setting.
This communication is not executed in this setting.
This communication is not executed in this setting.
Dedicated protocol ——
Data length
7-bit 
8-bit 
Parity
None 
Odd 
Even 
Stop bit
1-bit 
2-bit 
Transmission speed
(bps)
38400
*1

19200 
9600 
4800 
2400
1200
600
300
Header Invalid/valid
Terminator Invalid/valid 
Control cable Invalid/valid
Hardware type
Regular/RS-232C 
RS-485 
Control mode Invalid Not selectable
Sum check Invalid/valid ——
Transmission control
procedure
Format 1 ——
Format 4 ——
Station number settings 00 to 0F ——
Time-out time setting
1 to 255
Reference page B C D E F G H I

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi FX2N-232-BD and is the answer not in the manual?

Mitsubishi FX2N-232-BD Specifications

General IconGeneral
BrandMitsubishi
ModelFX2N-232-BD
CategoryController
LanguageEnglish

Related product manuals