F-3
FX Series PLC User's Manual - Data Communication Edition
Non-Protocol Communication (RS/RS2 Instruction)
1 Outline
1.1 Outline of System
A
Common Items
B
N:N Network
C
Parallel Link
D
Computer Link
E
Inverter
Communication
F
Non-Protocol
Communication
(RS/RS2 Instruction)
G
Non-Protocol
Communication
(FX
2N
-232IF)
H
Programming
Communication
I
Remote
Maintenance
Apx.
Discontinued
models
1. Outline
This chapter explains Non-protocol communication.
1.1 Outline of System
Non-protocol communication exchanges non-protocol data using a printer, bar code reader, etc.
In FX Series PLCs, non-protocol communication is available using the RS and RS2 instructions.
The RS2 instruction is dedicated to the FX
3G, FX3U and FX3UC PLCs, and allows communication using two
channels
*1
at the same time when the channels are specified.
*1. In FX
3G PLCs, the RS2 instruction allows communication using three channels at the same time.
1) Up to 4096 points of data can be sent, and up to 4096 points of data can be received. However, make
sure that the total number of sent and received data is 8000 points or less.
2) Data transfer is enabled when the connected equipment supports non-protocol serial communication.
3) The applicable total extension distance is 15m (49' 2") maximum in accordance with RS-232C
communication, and 500m (1640' 5") maximum in accordance with RS-485 comminication [50m (164' 0")
when 485BD connection is used].
RS instruction (FX
2(FX), FX2C, FX0N, FX1S, FX1N, FX2N, FX3G, FX3U, FX1NC, FX2NC, FX3UC)
.......
For selection, refer to
Chapter 3.
Communication
equipment operating
in accordance with
RS-232C or
RS-485
Printer or bar code reader
FX PLC
RS-232C: 15 m (49' 2"), RS-485: 500 m (1640' 5")
[50 m (164' 0") when 485BD is used]
Total extension distance
For specifications,
refer to Chapter 2.
Bar code reader
or printer
Word devices
4096 points data
.......
The amount of send data or
receive data can be 4096
points maximum.
For details, refer to Chapter 2.
.......
For wiring, refer to
Chapter 4.
+
Transfer direction
.......
To check applicable PLC
models, refer to Section 1.3.
In PLCs except for the FX
2N, FX3G, FX3U, FX2NC and FX3UC PLCs, the amount of send data or receive data can be 256
points maximum.
Important points and reference
chapter/section
System
.......

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi FX2N-232-BD and is the answer not in the manual?

Mitsubishi FX2N-232-BD Specifications

General IconGeneral
BrandMitsubishi
ModelFX2N-232-BD
CategoryController
LanguageEnglish

Related product manuals