EasyManua.ls Logo

Mitsubishi FREQROL-SFJ - Page 95

Mitsubishi FREQROL-SFJ
125 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Alarm
Abbr.
Name
Description
Motion
No.
(Note)
57
OPE
OPTION CARD This alarm occurs if "sync.
TAP",
A
ERROR
"C-axis control" or
"index"
sig-
nal is input though FR-SFJ is
not equipped with the correspon-
ding option card.
EO IPF
INSTAN.
This warning arises in case of
C
POWER FAIL-
URE
instantaneous supply voltage
drop.
'E4
WPE
WARNING
This warning arises if parameter
C
PARAMETER
ERROR
setting is beyond the specified
limit.
E7
NCE
NC
EMERGEN-
0 If emergency stop signal is
in-
CY
-put
to FR-SFJ from CNC (when
FR-SFJ is connected to CNC
through'bus line), this warn-
ing is given.
0 If emergency stop signal is in-
put from external signal source
(when parameter
kc42
(BSL)
is
set so that external emergency
signal is acceptable), this
warning is given.
Note:
If protective function listed above is activated,
Alarm No.
is
displayed by 'I-segment readout and the
following occurs.
Motion A . . . . .
Controller base current is shut off, main
(power) circuit contactor opens and the motor
stops after coasting.
Fault signal contact FA-FC opens.
Motion B . . . . .
Motor is decelerated by regenerative brake and
stops.
After motor stops, base current is'
interrupted.
In this case,
whether fault signal contact
FA-FC opens or not depends on parameter set-
-
92
-