AUTOMATIC FREE-WHEELING HUB INDICATOR SYSTEM
- Pulse Generator
8-215
PULSE GENERATOR
REMOVAL AND INSTALLATION
NOBRJM
Removal steps
I. Pulse generator
2. O-ring
NOTE
(1) Reverse the removal procedures to reinstall
(2)
q
: Non-reusable parts
I
16WO92
i
l
Check whether or not metal particles are adhered to the
pole (iron core) of the pulse generator.
l
Check whether or not the installation bolts of the pulse
rotor or the pulse generator are loose.
(For detailed information concerning the pulse rotor, refer
to GROUP 21 TRANSMISSION - Transfer.)
CHECKING PULSE GENERATOR RESISTANCE
Check whether or not the resistance between the terminals
shown in the figure is within the standard value range.
Standard value : 215 - 275 LR
If the resistance is not within the standard value range, replace
the pulse generator.