10. COMMUNICATION FUNCTION (MITSUBISHI ELECTRIC GENERAL-PURPOSE AC SERVO PROTOCOL) 
 
10 -  18 
 
(5)  Reading output device status 
Reads the on/off statuses of the output devices. 
 
(a) Transmission 
Transmit command [1] [2] + data No. [8] [0] to [8] [3]. 
 
Command Data No. 
[1] [2]  [8] [0] to [8] [3] 
 
(b) Return 
The slave station returns the status of the input/output devices. 
b31 b1b0
1: On
0: Off
Command of each bit is transmitted to the master station as hexadecimal data.
 
Bit 
Symbol 
Data No. [8] [0]  Data No. [8] [1]  Data No. [8] [2]  Data No. [8] [3] 
0 RD      MCD00 
1 SA      MCD01 
2 ZSP      MCD02 
3 TLC    CPO  MCD03 
4 VLC    ZP  MCD10 
5 INP    POT  MCD11 
6     PUS  MCD12 
7 WNG    MEND  MCD13 
8 ALM       
9 OP       
10 MBR       
11  
12 ALCD0    PED   
13 ALCD1       
14 ALCD2       
15  
16  
17     ALMWNG   
18  
19  MSDH    
20  MSDL    
21   SOUT     
22  OUT1    
23  OUT2    
24   OUT3  PT0 (Note)   
25 CDPS  CAMS  PT1 (Note)   
26   CLTS  PT2 (Note)   
27   CLTSM  PT3 (Note)   
28   CPCC  PT4 (Note)   
29  
30  
31 MTTR       
 
Note.  For MR-JE-_A servo amplifiers, up to four points of DO are available; therefore, PT0 to PT4 cannot be outputted 
simultaneously.