3. DISPLAY AND OPERATION SECTIONS
3 - 17
3.1.6 Parameter mode
(1) Parameter mode transition
After selecting the corresponding parameter mode with the "MODE" button, pressing the "UP" or
"DOWN" button changes the display as shown below.
[Pr. PB01]
[Pr. PA02]
[Pr. PA01]
I/O setting
parameters
[Pr. PD01]
[Pr. PD02]
[Pr. PD47]
[Pr. PD48]
[Pr. PC01]
[Pr. PC02]
[Pr. PC79]
Extension setting
parameters
[Pr. PC80]
[Pr. PB02]
[Pr. PB63]
[Pr. PB64]
To status display mode
[Pr. PA31]
Basic setting
parameters
[Pr. PA32]
Extension setting 2
parameters
[Pr. PE01]
[Pr. PE02]
[Pr. PE63]
[Pr. PE64]
Extension setting 3
parameters
[Pr. PF01]
[Pr. PF02]
[Pr. PF47]
[Pr. PF48]
Gain/filter
parameters
MODE
Positioning control
parameters
[Pr. PT01]
[Pr. PT02]
[Pr. PT47]
[Pr. PT48]
UP
DOWN
From alarm mode
(2) Operation method
(a) Parameters of 5 or less digits
The following example shows the operation procedure performed after power-on to change the
control mode to the positioning mode (point table method) with [Pr. PA01 Operation mode]. Press
"MODE" to switch to the basic setting parameter display.
The parameter number is displayed.
Press "UP" or "DOWN" to change the number.
The set value of the specified parameter number blinks.
Press "SET" twice.
To decide the value , press "SET".
Press "UP" six times.
During blinking, the set value can be changed.
Use "UP" or "DOWN".
( _ _ _ 6: Positioning mode (point table method))
……
……
……
To shift to the next parameter, press the "UP" or "DOWN" button.
After changing [Pr. PA01], cycle the power to enable the setting.