6 - 9
MELSEC-Q
6 SEQUENCE PROGRAM USED FOR POSITIONING CONTROL
Device
Device
name
Axis 1 Axis 2 Axis 3 Axis 4
Application Details of storage
D15
Acceleration time setting
(low-order 16 bits)
D16
Acceleration time setting
(high-order 16 bits)
(
Cd.10
New acceleration time
value)
D17
Deceleration time setting
(low-order 16 bits)
D18
Deceleration time setting
(high-order 16 bits)
(
Cd.11
New deceleration time
value)
D19
Acceleration/deceleration time change
enable
(
Cd.12
Acceleration/deceleration
time change during speed change,
enable/disable selection)
D20 Step mode
(
Cd.34
Step mode)
D21 Step valid flag (
Cd.35
Step valid flag)
D22 Unused
D23 Target position (low-order 16 bits)
D24 Target position (high-order 16 bits)
(
Cd.27
Target position change
value (new address))
D25 Target speed (low-order 16 bits)
D26 Target speed (high-order 16 bits)
(
Cd.28
Target position change
value (new speed))
D27 Target position change request
(
Cd.29
Target position change
request flag)
D28
Unused
D29 Unused
D30 ZP.PSTRT1 instruction control data
D31 Completion status
D32 Start number
D33 ZP.TEACH1 instruction control data
D34 Completion status
D35 Teaching data
D36 Positioning data No.
D37 ZP.PINIT instruction control data
D38 Completion status
D39 ZP.PFWRT instruction control data
D40 Completion status
D41 Z.ABRST1 control data
D42 Completion status
D43 Signals received from servo
D44 Signals transmitted to servo
D45 Status
D46 System area
D47 System area
D48 System area
D49 Error code
Error code at absolute position
restoration
D79 Error code (
Md.23
Axis error No.)
D50 Unit setting (
Pr.1
Unit setting)
Data register
D51
No. of pulses per rotation (
Pr.2
No. of pulses per rotation)

Table of Contents