- 72 -
9 For emergency
1
5
2
6
3
7
9
4
8
10
When you contact your nearest dealer
When you contact your nearest dealer for the trouble occurred during
operation of the refrigeration unit, give them the following information.
●
Company name
●
Kind of cargo
●
Customer’s name
●
Setting temperature
●
Company telephone number
●
Present inside container
temperature
●
Number of the plate
●
Type of the refrigeration unit
●
Specific condition of trouble
●
Present location of the vehicle
●
Alarm code displayed in the
digital display area.
●
Destination
F11F12
F17
F4
F16
F15
F14
F2 F3F10F5
F9F6F8
F13 F7
F1 : 20 A (operation circuit) is xed with the fuse holder.
F2 : 15 A (Relay circuit)
F3 : 10 A (Compressor electromagnetic clutch)
F4 : 10 A (Drain hose heater A)
F5-8 : 15 A (Evaporator fan motor 1-4)
F9 : 30 A (Throttle solenoid)
F10 : 10 A (Output during operation)
F11 : 10 A (Output at error occurrence)
F12 :
10 A (Output at deviation from adequate temperature)
F13-15 : 15 A (Evaporator fan motor 5-7)
F16 : 15 A (Evaporator fan motor 8) * 2-room specication
F16 : 10 A (Drain hose heater C) * 3-room specication
F17 : 10 A (Drain hose heater B)
F1 fuse holder
■Multiple specification (TU100SAEM)