- 79 -
10 Specification
1
5
2
6
3
7
9
4
8
10
(1) Freezing capacity is for the single operation.
(2) Charge amount of refrigerant varies depending on the combination of evaporator
Model
Item
TU100SAEM
Sound power level
Refrigerant charge volume
Inside container temperature control
Operation control
Defrosting device
Safety device
98
4.3~5.6 (R404A)
Electronic thermostat
Microcomputer controller
Hot gas defrost type (Automatic timer and manual)
High pressure switch, engine oil pressure switch, engine
water temperature switch, fusible plug, motor
over-current relay, DC circuit fuse, DC circuit fusible link,
front panel open detection switch, automatic power
supply anti-phase reversal switching and engine clutch
temperature sensor