Instructions for use
Laboratory drying ovens and incubators
line Comfort
LSI_K_np_en 1206_mmm_V2.08_B2V
ECOCELL 22, 55, 111, 222, 404, 707
DUROCELL 22, 55, 111, 222
VENTICELL 22, 55, 111, 222, 222/2, 404,
404/2, 707, 707/2
INCUCELL 22, 55, 111, 222, 404, 707
INCUCELL V 22, 55, 111, 222, 404, 707
ECOCELL 22, 55, 111, 222, 404, 707
DUROCELL 22, 55, 111, 222
VENTICELL 22, 55, 111, 222, 404, 707
INCUCELL 22, 55, 111, 222, 404, 707
INCUCELL V 22, 55, 111, 222, 404, 707
Návod na servis
Laboratorní sušárny a inkubátory - linie
Standard
LSI-S_ns_cz_0801_V2.01_B2V
Návod k použití
Laboratorní sušárny a inkubátory
linie Komfort
LSI_K_np_cz 0608_V1.14
ECOCELL 22, 55, 111, 222, 404, 707
DUROCELL 22, 55, 111, 222
VENTICELL 22, 55, 111, 222, 404, 707
STERICELL 22, 55, 111, 222, 404
INCUCELL 22, 55, 111, 222, 404, 707
INCUCELL V 22, 55, 111, 222, 404, 707

Table of Contents

Other manuals for MMM Group venticell 404

Question and Answer IconNeed help?

Do you have a question about the MMM Group venticell 404 and is the answer not in the manual?

Summary

GENERAL

1.1 PURPOSE AND USE

Details the intended use of the ovens for warming materials with hot air.

IMPORTANT INSTRUCTIONS

2.2 PRE INSTALLATION

Guidance on indoor installation, power connection, and initial operational checks.

DESCRIPTION OF THE OVEN

3.2 POWER CONNETION AND CONNECTORS

Details the electrical connections, power supply, and various connectors on the unit.

3.3 CONTROL PANEL

Explains the functions of the control panel buttons, indicators, and display.

FUNCTION AND OPERATING

4.1 BASIC SETTING OF THE UNITS

Covers fundamental inputs and settings required for unit operation via the Comfort regulator.

4.1.1 ACTIVATING THE SERVICE MODE

Procedure to activate the service mode for unit configuration and settings.

4.1.2 SERVICE 01 - STORING P1-P6

Instructions for storing programs P1 to P6 onto a chip card.

4.1.8 SAFETY THERMOSTAT SETTING

Details on setting the safety thermostat to prevent overheating and protect the unit.

4.1.9 TEMPERATURE TOLERANCE

Defines how to set temperature deviation limits and error handling for deviations.

4.2 PROGRAM P1

Describes the operation of Program P1 for constant temperature control.

4.2.1 SET P1

Instructions for setting the temperature and parameters for Program P1.

4.2.3 START P1

How to start Program P1 and what signals to expect.

4.3 PROGRAM P2

Details Program P2 operation, including temperature, time, and fan speed settings.

4.3.1 SET P2

Steps to set temperature, run down time, and fan speed for Program P2.

4.3.3 START P2

How to start Program P2 and interpret its initial display.

4.4 PROGRAM P3

Explains Program P3, including delayed start and temperature/time settings.

4.4.1 SET P3

Instructions for setting delay time, segments, temperature, and fan speed for Program P3.

4.4.3 START P3

How to start Program P3 and view the active segment status.

4.5 PROGRAM P4

Details Program P4 with two temperature levels, controlled ramp speeds, and cycling.

4.5.1 SET P4

Instructions for setting initial temperature, levels T1 and T2, and dwell times for Program P4.

4.5.2 SET THE SEGMENT FOR T1

Configuration of temperature, dwell time, ramp, and fan speed for the T1 segment.

4.5.3 SET THE SEGMENT FOR T2

Configuration of temperature, dwell time, ramp, cycles, and fan speed for the T2 segment.

4.6 PROGRAM P5

Describes Program P5, consisting of 40 segments defined by temperature, time, speed, humidity, and light.

4.6.1 DESCRIPTION OF P5 AND ITS CONTROL

Explains the structure of Program P5 and its control parameters.

4.7 PROGRAM P6

Details Program P6, which uses real time and calendar date for segment duration.

4.7.1 DESCRIPTION OF P6

Explains the structure of Program P6, including delayed start and segment properties.

4.7.2 PROGRAMME SETTING

Guides on setting Program P6, including delayed start and segment configurations.

4.7.4 POWER SUPPLY FAILURE

Describes how power supply failures affect Program P6 operation and restarts.

4.10 ERROR MESSAGES

Lists and explains common error messages displayed by the unit.

PARAMETERS OF THE UNIT

CLEANING AND DECONTAMINATION OF THE UNIT

MAINTENANCE

WARRANTY AND SERVICE

OPTIONAL EQUIPMENT

11.16 VENTICELL WITH STERILIZATION FUNCTION

Describes how Venticell models are equipped with sterilization programs SS and SP.

11.16.1 BASIC STERILIZATION PROGRAMME SS

Details the basic SS sterilization program, including its setting and course.

11.16.1.1 SS PROGRAMME SETTING

Instructions for setting the SS sterilization program, including delay time and temperature.

11.16.1.6 STERILIZATION PROGRAMME SETTING AND COURSE

Details the course of the sterilization program, including flap/door status and temperature drop handling.

11.16.2 STERILIZATION PROGRAMME SP WITH PREHEATING PHASE

Describes the SP sterilization program with a preheating phase for even load heating.

11.16.2.1 SP PROGRAMME SETTING

Instructions for setting the SP sterilization program, including T1 and T2 segments.

11.16.2.2 SEGMENT SETTING FOR T1

Setting the temperature and delay time for the T1 (preheating) segment of Program SP.

11.16.2.3 SEGMENT SETTING FOR T2

Setting the temperature and delay time for the T2 (sterilization) segment of Program SP.

EMERGENCY DOOR OPENING