-17-
Revision 2/F3509
FAULT POSSIBLE CAUSE REMEDY
ELEMENT NOT WORKING Element faulty (blown).
(Refer fault diagnosis 6.1.9)
Replace.
(Refer service section 6.3.15)
NO THERMOSTAT HEATING
INDICATOR
Indicator faulty.
(Refer fault diagnosis 6.1.12)
Replace.
(Refer service section 6.3.3)
ROAST TIMER (180 MINUTE)
WILL NOT TIME DOWN
NO HOLD INDICATOR
HOLDING TEMPERATURE
INCORRECT
Roast ’n’ Hold switch not de-
pressed.
No power to timer / timer faulty..
(Refer fault diagnosis 6.1.13)
‘Roast ‘n Hold’ switch faulty.
(Refer fault diagnosis 6.1.13)
Faulty indicator.
(Refer fault diagnosis 6.1.14)
Faulty timer.
(Refer fault diagnosis 6.1.14)
Hold thermostat set tempera-
ture incorrect.
Hold thermostat faulty.
(Refer fault diagnosis 6.1.15)
Depress switch. Switch will
illuminate.
Correct electrical fault / replace
timer.
(Refer service section 6.3.8)
Replace.
(Refer service section 6.3.4)
Replace.
(Refer service section 6.3.3)
Replace.
(Refer service section 6.3.8)
Adjust to correct temperature.
(Refer service section 6.4.5)
Replace.
(Refer service section 6.3.10)
DOOR DOES NOT CLOSE Tray in way of door.
Door seal obstruction.
Door handle installed
incorrectly.
Door catch setting incorrect.
Door pivot bushes / pins worn.
Correctly position tray in rack.
Correctly install door seal.
(Refer service section 6.3.20)
Fit correctly.
(Refer installation section)
Adjust.
(Refer service section 6.4.3)
Replace.
(Refer service section 6.3.21)
DOOR SEAL LEAKS
Door seal damaged.
Door seal incorrectly fitted.
Door catch setting incorrect.
Door pivot bushes / pins worn.
Door catch striker plate worn.
Replace.
(Refer service section 6.3.20)
Correctly install door seal.
(Refer service section 6.3.20)
Adjust.
(Refer service section 6.4.3)
Replace.
(Refer service section 6.3.21)
Replace.
(Refer installation instruc-
tions—Door handle installa-
tion)