– 31 –
TABLE OF DEVICE ADDRESSES
This Device Uses Address Reports as †† Enabled By…
RF Receiver 00 100 *56 zone programming: input device type entry
AUI (touchscreen) 1 01 n/a Automatic if field *189 enabled for AUI 1
AUI (touchscreen) 2 02 n/a Automatic if field *189 enabled for AUI 2
AUI (touchscreen) 3 05** n/a Automatic if field *189 enabled for AUI 3
AUI (touchscreen) 4 06** n/a Automatic if field *189 enabled for AUI 4
Communication Device (LRR) 03 103 automatic if communication device enabled in *29 menu mode
4286 Voice Module 04 104 automatic if phone module access code field *28 enabled
Zone Expanders (4219/4229):
module 1 (for zones 09 - 16)
module 2 (for zones 17 - 24)
module 3 (for zones 25 - 32)
module 4 (for zones 33 - 40)
module 5 (for zones 41 - 48)
07
08
09**
10**
11**
107
108
109
110
111
*56 zone programming: input device type entry, then:
automatic if zone no. 9-16 entered as AW type or relay assigned
automatic if zone no. 17-24 entered as AW type or relay assigned
automatic if zone no. 25-32 entered as AW type or relay assigned
automatic if zone no. 33-40 entered as AW type or relay assigned
automatic if zone no. 41-48 entered as AW type or relay assigned
Relay Modules (4204):
module 1
module 2
module 3
module 4
12
13
14**
15**
112
113
114
115
*79 output device programming: device address prompt:
entered at device address prompt
entered at device address prompt
entered at device address prompt
entered at device address prompt
Keypads:
keypad 1
keypad 2
keypad 3
keypad 4
keypad 5
keypad 6
keypad 7
keypad 8
16
17
18
19
20
21
22
23
n/a
n/a
n/a
n/a
n/a
n/a
n/a
n/a
data field programming as listed below:
always enabled, all sounds enabled.
data field *190
data field *191
data field *192
data field *193
data field *194
data field *195
data field *196
RIS Communication 25 n/a automatic
5800TM Module 28 n/a automatic
** These module addresses apply to VISTA-20PMT only.
†† Addressable devices are identified by “1” plus the device address when reporting. Enter report code for zone 91 to enable addressable device
reporting (default = reports enabled). See field *199 for addressable device (ECP) 3-digit/2-digit identification keypad display options.
5800 SERIES TRANSMITTER INPUT LOOP IDENTIFICATION
All of the transmitters illustrated have one or more unique factory assigned input (loop) ID numbers. Each of the inputs
requires its own programming zone
(e.g., a 5804's four inputs require four programming zones). For information on any
transmitter not shown, refer to the instructions accompanying that transmitter for details regarding loop numbers, etc.
UL NOTE: The following transmitters are not intended for use in UL installations: 5802MN, 5802MN2, 5804, 5804BD, 5814, 5816TEMP,
5819, 5819WHS & BRS, and 5850.
The 5827BD and 5800TM can be used in UL Listed Residential Burglar installations.
LOOP 1
5806/5806W3
5808/5808LST/5808W3
ENROLL AS
"RF"
LOOP 1
5809
ENROLL AS
"RF"
5818MNL
ENROLL AS
"RF"
LOOP 1
LOOP 1
5814
ENROLL AS
"RF"
5800-004-V0
LOOP 1
(MOTION)
5897-35
ENROLL AS
"RF"
5890/5890PI
ENROLL AS
"RF"
LOOP 1
5802 MN
ENROLL AS
"UR" OR "RF"
5805-6
ENROLL AS
"BR"
5804BD/5804BDV
ENROLL AS
"BR"
SET HOUSE ID
LOOP 4
YOU MUST
ENROLL
THIS
BUTTON
LOOP
3
LOOP 1
LOOP 2
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
5804/5804E
ENROLL AS "BR"
5817
ENROLL AS
"RF"
LOOP 2
(AUX.
CENTER)
LOOP 1
(PRIMARY)
LOOP 3
(AUX.
RIGHT)
5816
ENROLL AS
"RF"
LOOP 1
(TERMINALS)
LOOP 1
(TERMINALS)
LOOP 2
(REED)
5816MN
ENROLL AS
"RF"
LOOP 1
(TERMINALS)
ALTERNATE
POSITION FOR
LOOP 2
LOOP 2
(REED)
LOOP 3
(TERMINALS)
5828/5828V
SET HOUSE ID
5815
ENROLL AS
"RF"
5820/5820L
ENROLL AS
"RF"
5819S (WHS & BRS)
ENROLL AS
"RF"
LOOP 1
(INTERNAL
SHOCK
SENSOR
LOOP 2
(REED)
5819
ENROLL AS
"RF"
LOOP 2
(REED)
LOOP 3
(TERMINALS)
LOOP 1
(TERMINALS)
5800WAVE
SET HOUSE ID
ENROLL AS"RF"
5800Micra
ENROLL AS "RF"
5800CO
ENROLL AS "RF"
5801
ENROLL AS
"UR OR"RF"
5800SS1
ENROLL AS "RF"
LOOP 3
LOOP 1
LOOP 2
LOOP 4
YOU MUST
ENROLL
THIS
BUTTON
5894PI
ENROLL AS
"RF"
5802 MN2
ENROLL AS
"UR" OR "RF"
LOOP 1
LOOP 1
LOOPS
1 - 3
LOOP 1
LOOP 1
LOOP 1
LOOP
1
LOOP 1
LOOP
1
LOOP
1
5878
ENROLL AS
"BR"
5853
ENROLL AS
"RF"
ARMED
READY
MESSAGE
MIC
43
21
OFFON
5821
ENROLL AS
"RF"
LOOP 4
YOU MUST
ENROLL
THIS
BUTTON
LOOP 1
LOOP 2
LOOP 3
SERIAL #1
LOOP 3
SERIAL #1
LOOP 4
SERIAL #2
LOOP 3
SERIAL #1
LOOP 2
SERIAL #1
LOOP 1
SERIAL #2
LOOP 2
SERIAL #1
LOOP 3
SERIAL #1
LOOP 4
SERIAL #2
LOOP 3
SERIAL #1
LOOP 2
SERIAL #1
LOOP 1
SERIAL #2
LOOP 2
3
AWAY
STAY
1
2
4
OFF
ON
LOOP 2
(REED)
LOOP 2
(REED)
SERIAL #2 - LOOP 1 = ON + 4 BUTTONS
LOOP 4 = 3 + 4 BUTTONS
SERIAL #2 - LOOP 1 = ON + 4 BUTTONS