EasyManua.ls Logo

Motomaster Nautilus - Error Codes F03-F06

Motomaster Nautilus
9 pages
Print Icon
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
16
TROUBLESHOOTING/ FAULT CODES
Model no. 011-1973-2 l Quest ions? Contact us 1-888 -942 -6686
Error Code Condition Cause Solution
Act ual charge rat e exceeds
selected charging rate.
The t emperature of the
charger is too high.
Charger error.
Disconnect t he load and
at t empt t o charge again.
Disconnect t he bat t ery and the AC
power; at t empt to charge again.
High ambient t emperature
or poor ventilation.
Ensure adequate vent ilation. The charger
will resume charging after cooling.
A load may be connected
to the batt ery.
Working Volt age AC
Input Voltage AC
Input Amps
Charging Voltage
Charging Current
Minimum Battery Volt age
Ambient Operat ing Temperature
Charger Type
Compat ible Bat t ery Volt age
Compat ible Bat t ery Types
Compat ible Bat t ery Capacities
Dimensions (L x W x H)
Weight
120 V AC, 60 Hz
104127 V AC, 60 Hz
6.5 A (max.)
NORMAL: 14.4 V
RECONDITIONING: 15.8 V
AGM: 14.8 V GEL: 14.1 V
CHARGING: 2/ 8/ 15 A
1.5 V
-20 to 40º C (-4 t o 104ºF)
6-step, fully aut omatic
12 V (nominal)
All lead-acid (Wet, MF, Ca, AGM and Gel)
Charging: 10 to 300 Amp-hour
Maint enance: 10 t o 500 Amp-hour
7 7/ 8 x 4 15/ 16 x 8 11/ 16" (20 x 12.5 x 22 cm)
2 lb 9 oz (1.15 kg)
TECHNICAL SPECIFICATIONS
The bat t ery does not go int o
Maint enance mode after
being charged for 24 hours.
Not e: When F05 appears,
disconnect charger from AC
power and battery, then
reconnect and attempt to
charge again.
Try charging battery again using
a higher charge rate.
Remove any loads connected t o
the batt ery during charging.
There is a load placed on
the batt ery while charging.
Battery is defective and
will not accept a charge.
The bat t ery clamps are
incorrect ly connected.
Reverse polarity.
Replace bat t ery.
Reverse clamp connect ions.
The charge current is too
low.
TECHNICAL SPECIFICATIONS

Related product manuals