Bench Setup 3-7
SG 2000 Installation and Operation Manual
Single Power Supply or Commonly Powered Redundant Supplies
To activate a single power supply or commonly powered redundant supplies, place jumper JP1
(illustrated in Figure 3-1) on the SG2-LIDB in the vertical position (strand-mount installation).
Figure 3-6 illustrates this position. Power supplies #1 and #2 are both connected to the primary ac
power feed.
Figure 3-6
JP1 common-powered single or redundant power configuration
Secondary AC
Primary AC
Power supply #2
Power supply #1
JP1
Individually Powered Supplies
To activate split ac powering of the node, place jumper JP1 on the SG2-LIDB in the horizontal
position (strand-mount installation). Figure 3-7 illustrates this position. Fuse jumper F7 must also be
removed. The primary ac power feed now connects to power supply #l and an independent
secondary ac source is connected to power supply #2. This configuration implies that the primary ac
power source originates from port
IN, port 1 or port 2. The secondary ac power source originates
from port
OUT or port 3. For this configuration the optional interconnect cable (SG2-SIC) must be
installed between the lid board and the RF chassis.
Figure 3-7
JP1 split-powered redundant power supply configuration
Secondary AC
Primary AC
Power supply #2
Power supply #1
JP1
Other power configurations are possible, but not recommended.
CAUTION!
Take extreme care so that you do not directly connect primary and secondary power
sources when implementing other configurations.