Operation 5-11 
  SG 2000 Installation and Operation Manual 
Tables 5-1 and 5-2 provide additional information on the user-related features and output levels of 
the SG2-LR: 
Table 5-1  
SG2-LR features 
Feature Description 
Optical power test point 
This test point enables monitoring of the optical power level 
at the input to the module. The nominal scale factor is 
1.0 V/mW. 
Hybrid current test point 
This test point enables monitoring the current drawn by the 
amplifier section of the integrated optical receiver hybrid. The 
nominal scale factor is 1.0 V/A. The hybrid current test-point 
voltage is between 0.150 V and 0.350 V (hybrid current of 
150 mA through 350 mA) when the module is enabled under 
normal operating conditions. 
Receiver enable 
A green LED that provides visual indication of the receiver’s 
enable status. 
Fault indicator 
A red LED that illuminates when the module is enabled but 
the hybrid current is outside the normal operating range. 
Optical power status 
A green LED that is ON (
NORM) when the optical power is 
within the recommended operating range (refer to Table A-4). 
Two red LEDs indicate that the optical power is above (
HIGH) 
or below (
LOW) the recommended optical input power range. 
Table 5-2  
SG2-LR minimum output levels 
Optical input 
level(dBm/mW) 
TP Volts 
(1 mW=1 V) 
Output (dBmV) 
77 channels 
Output (dBmV) 
110 channels 
Comments 
 3.2/2.1 
2.1  32  30  Low level alarm 
 3.0/2.0 
2.0  31  30  Low level alarm 
 2.8/1.9 
1.9  31  29  Low level alarm 
 2.6/1.8 
1.8  30  29  Low level alarm 
 2.3/1.7 
1.7  30  28  Low level alarm 
 2.0/1.6 
1.6 29  28 Normal 
 1.8/1.5 
1.5 29  27 Normal 
 1.5/1.4 
1.4 28  26 Normal 
 1.0/1.3 
1.3 27  25 Normal 
 0.8/1.2 
1.2 27  25 Normal 
 0.5/1.1 
1.1 26  24 Normal 
 0.0/1.0 
1.0 
25 23 Optimum 
–0.5/0.9 
0.9 24  22 Normal 
–1.0/0.8 
0.8 23  21 Normal 
–1.5/0.7 
0.7 22  20 Normal