8 Alarms
General
To cancel an alarm press enter .
When an alarm is active there will be a 24VDC signal between connection 18 and 19 on the main board to
activate the flash light. (See appendix A).
The controller itself gives a beeping signal and the alarm LED will lighten up.
Filling alarm
The MC18-Micro is able to give an alarm when there is not sufficient material inside the hopper.
Alarm settings when using an automatic hopper loader.
See paragraph 7.9
Alarm settings manual hopper filling (without automatic hopper loader)
In case of manual filling of the hopper, the hopper loader control of the MC18-Micro is used to generate
the filling alarm. A sensor and an alarm output is needed.
Use the settings below.
ME: ME hopper loader = ON
FILt = 0,1
FILA = 0,2
The Filling alarm is self-eliminating, this means that the alarm will stop automatically when the sensor is covered with material.
If an alarm is canceled by pressing enter the next alarm will come (if the sensor is still not covered)
with a delay of 60 seconds. This gives the operator the time to manual fill the hopper without having the
alarm on.
Motor connection failure [Err0]
Err0 : Motor connection failure.
Make sure the motor is connected
Check cable and connectors for damage.
Press enter to stop the alarm.