MGate 5111 Web Console Configuration
Protocol Settings
The MGate 5111 supports PROFIBUS, Modbus RTU/ASCII, Modbus TCP, EtherNet/IP and PROFINET protocols.
Each role is determined by your device's settings. Modbus TCP (Client/Server), Modbus RTU/ASCII
(Master/Slave), EtherNet/IP (Adapter), and PROFINET (IO Device) can be selected.
The setting of each protocol is described as follows:
1. PROFIBUS Slave
Slave Settings
Parameter Value Default Description
Slave address PROFIBUS address
125 supported by SW)
Depends on the
rotary switch
Before any communication, you
must assign a slave ID to the
PROFIBUS slave. If you would
like to assign an address
between 0-99, you need to
change the rotary switch to the
desired address. If you would
like to assign an address which
is over 99, you must set it via