mr
.
steam
®
steamtherapy
®
Installation, Operation & Maintenance Manual
__________________________________________________________________________
2
M
M
a
a
t
t
e
e
r
r
i
i
a
a
l
l
s
s
o
o
f
f
c
c
o
o
n
n
s
s
t
t
r
r
u
u
c
c
t
t
i
i
o
o
n
n
,
,
r
r
o
o
o
o
m
m
s
s
i
i
z
z
e
e
(
(
i
i
n
n
c
c
l
l
u
u
d
d
i
i
n
n
g
g
r
r
o
o
o
o
m
m
h
h
e
e
i
i
g
g
h
h
t
t
)
)
a
a
n
n
d
d
s
s
p
p
e
e
c
c
i
i
a
a
l
l
d
d
e
e
s
s
i
i
g
g
n
n
f
f
e
e
a
a
t
t
u
u
r
r
e
e
s
s
s
s
u
u
c
c
h
h
a
a
s
s
l
l
a
a
r
r
g
g
e
e
g
g
l
l
a
a
s
s
s
s
a
a
r
r
e
e
a
a
s
s
,
,
a
a
l
l
l
l
a
a
f
f
f
f
e
e
c
c
t
t
t
t
h
h
e
e
s
s
t
t
e
e
a
a
m
m
g
g
e
e
n
n
e
e
r
r
a
a
t
t
o
o
r
r
m
m
o
o
d
d
e
e
l
l
s
s
e
e
l
l
e
e
c
c
t
t
i
i
o
o
n
n
.
.
1
. Measure length, width & height in feet of the steam/shower or tub/shower
Multiply the Length ____ x Width_____ x Height _____ =
2.
Adjustments to Room Volume:
For natural stones: natural marble,
Add 100%
stone, shale, glass block or concrete
For ceramic or porcelain tile on
Add 30%
cement board or mortar bed
For each exterior wall or Add15% each
extra glass panel wall or panel
For each foot exceeding 8ft. in height Add 15% each foot
3. Add all figures above to obtain the Total Room Volume required
ROOM VOLUME
TOTAL ADJUSTED
ROOM VOLUME
SELECT YOUR MR.STEAM
®
Compare your TOTAL ADJUSTED ROOM VOLUME to the Specification Chart below
and select the appropriate model.
Visit www.mrsteam.com for sizing & selection calculators and additional information.
I
MPORTANT: The guidelines for selecting the steambath gen-
erator is a recommendation only. Because of variables in con-
struction, these sizing instructions and specifications should
b
e considered as guidelines only. Mr.Steam
®
w
ill review the
model selected provided we receive complete information,
including working drawings, specifications, and pertinent elec-
trical and construction details. Otherwise, the manufacturer
disclaims responsibility for the sizing of a model selected.
IMPORTANT: For steam rooms constructed of acrylic or syn-
thetic materials, select next lower-rated MS model.
WARNING: In considering a purchase of this steambath sys-
tem, please note that if you are pregnant, have a coronary
condition, are in poor health, are being treated for any other
medical condition, or are using medication or drugs, Mr.Steam
recommends that you obtain the approval of a physician
before use. For information about this product and safety
issues, please call us at 1.800.76.STEAM or log onto
www.mrsteam.com for a copy of the Installation/Operation/
Maintenance Manual.
IMPORTANT: The total adjusted room volume allows for up to
60 feet of insulated steam line from the MS generator to the
steam room. If the 60 foot line is exceeded consult with facto-
ry. When locating the steam generator consideration of con-
trol location must be taken into account, the maximum length
for a control cable is 60 feet. A 30 foot cable is standard, con-
tact Mr.Stam to purchase the optional 60 ft. cable (PN
103990-60)
Residential Steam Generators Specification Chart
Amps (for Total Adj Wire Water Usage Shipping
Model No. KW 240v/1PH)† Room Vol. Size‡ gallons†† Dimensions* Wt. (lbs)**
MS90E 5 21 100 10 0.67 14½"L x 14¾"H x 6¾"D 30
MS150E 6 25 150 8 0.80 14½"L x 14¾"H x 6¾"D 30
MS225E 7.5 32 225 8 1.0 14½"L x 14¾"H x 6¾"D 30
MS400E 9 38 360 8 1.2 14½"L x 14¾"H x 6¾"D 30
MS SUPER 1E 10 42 475 8 1.4 17"L x 18½"H x 7
7
⁄8"D 40
MS SUPER 2E 12 50 575 6 1.6 17"L x 18½"H x 7
7
⁄8"D 40
MS SUPER 3E 15 63 675 4 2.0 17"L x 18½"H x 7
7
⁄8"D 40
MS SUPER 4E 20 84 875 8 2.7 17"L x 18½"H x 7
7
⁄8"D x 2 80
MS SUPER 5E 24 100 1075 6 3.2 17"L x 18½"H x 7
7
⁄8"D x 2 80
MS SUPER 6E 30 125 1275 4 4.0 17"L x 18½"H x 7
7
⁄8"D x 2 80
IMPORTANT: Add C1 suffix to Model No. for 240V/1Ph; Add B1 suffix to Model No. for 208V/1Ph.
IMPORTANT: Models SUPER 1E-6E must use eTEMPO/Plus® control.
IMPORTANT: All Mr.Steam MS Models are cULus Listed and CE approved.
NOTES:
All MS Generators available in 240v/1PH, 208v/1PH and other voltages/phases.
† Amps are for 240/1PH rated units.
‡Wire size (AWG) based on minimum 90˚C rated THHN copper conductors.
Refer to the National Electrical Code for other types of conductors.
See Mr. Steam® Installation and Operation Manual for complete dimensional and installation information.
MS SUPER 4E includes two MS SUPER 1E steam generators, and require one eTEMPO/Plus® Control, and two matching steamheads. MS SUPER 5E includes two MS
SUPER 2E steam generators, and require one eTEMPO/Plus® Control, and two matching steamheads. MS SUPER 6E includes two MS SUPER 3E steam generators,
and require one eTEMPO/Plus® Control, and two matching steamheads.
*Dimensions are for generator only, without
AutoFlush® or plumbing features.
**Shipping weight and pricing are for generator
only, without control or steamhead.
†† Water usage based on 20 minutes of operation.