B : Press ◄ or ► KEY then enter "N" option is selected and flashes, press
or KEY then enter "Y" option and is now flashing
C : Press ◄ or ► KEY will return to AUTO POWER OFF option and is flashing ,
press KEY then go to the next option as SCREEN1
(AUTO POWER OFFTrans Ref)
4-5-10 Trans Ref: Nominal voltage for transient detection reference
SCREEN 1(4-5-10)
A : When entering the Trans Ref option and is flashing(as SCREEN1).
B : When you press ◄ or ► KEY then enter the digital adjustment and showed
flashes, press or KEY can be adjusted its range(50.0V ~ 850.0V)
Remark: Press or KEY> 2 SEC then the number will quickly change.
C : Press ◄ or ► KEY will return to AUTO POWER OFF option and is
flashing , press KEY then go to the next option(Trans RefSVDP)
4-5-11 SVDP:Set up upper and low limits % of transient voltage detection
SCREEN 1(4-5-11)
A : When entering the SVDP option and is flashing(as SCREEN1).
B : Press ◄ or ► KEY then enter the digital adjustment and showed flashes,
press or KEY can be adjusted its range (1%100%)