Test bench MS002 COM
24
5. When the bench runs
the abnormal noises are
heard
The belt tightening bearings
failed
Replace the bearings
The electric motor bearings
failed
Replace the bearings. (Electric
motor)
The contactor (motor starter)
failed
Replace the contactor (motor
starter)
6. When the bench runs
the belt slips.
The wear of the belt Replace the belt
7. The current
consumption is
displayed wrong
There’s no proper contact at
the current sensor connection
terminal
Recover the contact
The current sensor failed
Contact technical support
The measuring board has burnt
8. The triple-pole switch
is activated when the
bench is turned on.
The bench wiring is damaged Contact technical support
There’s too much dust inside
the bench
Clean the bench of the dust
9. When the diagnostics
modes start, the
electromagnetic
switches don’t turn on
The ATX connector of the bench
control unit disconnected
Fix the connector in the control
unit
The wiring is damaged Contact technical support
10. During the alternator
test the contact clips
heat up much
The contact area is small
Use a positive terminal adapter
of the alternator