7.1. Cleaning and care
Use soft tissues or wipe cloths to clean the surface of the device with neutral detergents. Clean
the display with a special fiber cloth and a cleaning spray for touch screens. To prevent corrosion,
failure, or damage to the test bench, do not use any abrasives or solvents.
8. TROUBLESHOOTING GUIDE
Table with the possible problems and the solutions on their elimination:
Problem Causes Solutions
1. The bench doesn’t
start.
There is no the required
voltage in the circuit - 400V
Restore the supply
The ATX connector of the
control unit disconnected.
Check the proper connection of
ATX connectors
The button EMERGENCY STOP is
on
Turn off the button EMERGENCY
STOP
The triple-pole bench incoming
switch is off
Turn on the triple-pole switch
2. At the test start, the
bench beeps with a
guard signal of a short
circuit (peep)
The short circuit of the battery
outputs (+) to the body
Separate the outputs (insulate)
3. The bench runs but
the electric motor
doesn’t start
The variable speed drive
software error
Contact technical support
The contacts on the terminal
block of the electric motor are
loosened
Tighten the contacts on the
terminal block of the electric
motor
The control patch cord of the
variable speed drive got loose
Connect the patch cord
properly
4. The incoming switch
turns off at the
maximum bench load
The type of the incoming switch
is not correct
Replace the incoming switch
The incoming switch terminals
are loosened
Tighten the terminals

Table of Contents