CROSS SENSITIVITY
1
- SENSOR ELEMENT (SC2/MC2)
Gas type
Ordering No.
Ammonia, NH
3
Chlorine, Cl
2
Ethanol, C
2
H
6
O
Ethylene, C
2
H
4
Carbon
dioxide, CO
2
Carbon
monoxide, CO
Sulphur
dioxide, SO
2
Hydrogen sulphide,
H
2
S
Nitrogen
dioxide NO
2
Nitrogen
monoxide, NO
Hydrogen, H
2
SC2-/
MC2-X-
ppm
ppm
ppm
ppm
ppm
ppm
ppm
ppm
ppm
ppm
CO
E1110-A
50/-0.5
15/0.0
200/<1.0
100/11.5
-
-
10/-0.1
15/0.5
10/-0.3
50/-3.0
100/8.5
CO
E1110-C
-
2/<0.5
-
-
-
-
-
25/0
20/<0.5
50/<10
100/<20
CO
E1110-E
-
2/<0.5
-
-
-
-
-
25/0
20/<0.5
50/<10
100/<20
CO
E1110-F
-
2/<0.5
-
-
-
-
-
25/0
20/<0.5
50/<10
100/<20
CO
E1110-H
-
2/<0.5
-
-
-
-
-
25/0
20/<0.5
50/<10
100/<20
NH
3
E1125-A
-
-
100/0
-
5000/0
500/0
20/-6
25/30
5/-7.5
50/0
100/0
NH
3
E1125-B
-
-
100/0
-
5000/0
500/0
20/-6
25/30
5/-5
50/0
100/0
NH
3
E1125-C
-
-
100/0
-
5000/0
500/0
20/-6
25/35
5/-5
50/0
100/0
NH
3
E1125-D
-
-
100/0
-
5000/0
500/0
20/-6
25/35
5/-5
50/0
100/0
NH
3
E1125-E
100/100
100/0
100/0
100/0
100/0
20/<30
25/<17.5
5/5.5
50/0
100/<-10
NO
E1129-C
-
-
-
-
-
200/0
20/0
25/<10
20/0
-
-
NO
2
E1130-A
50/0
1/0.5
-
-
5000/0
300/0
20/0
15/<1
-
50/<-1
200/0
NO
2
E1130-B
50/0
1/0.5
-
-
5000/0
300/0
20/0
15/<1
-
50/<-1
200/0
NO
2
E1130-C
50/0
1/0.5
-
-
5000/0
300/0
20/0
15/<1
-
50/<-1
200/0
NO
2
E1130-E
50/0
1/0.5
-
-
5000/0
300/0
20/0
15/<1
-
50/<-1
200/0
NO
2
E1130-F
100/0
1/1
100/0
-
5000/0
300/0
20/0
10/-7~0
10/10
30/0
1000/0
VOC
E1160-X
2
-
-
5/1,83
5/0,59
-
-
-
-
-
-
-
HCN
E1183-X
2
-
-
-
100/0
-
100/~2
20/~38
15/~25
5/~-12
25/0
100/~2
CH
2
O
E1185-B
-
-
30/1
-
-
100/<20
-
20/~20
-
-
100/5
HCl
E1186-D
80/0
20/<0.5
30/<0.3
100/0
-
1000/0
100/0
20/<40
20/-6
25/0
-
C
2
H
4
E1189-C
-
-
-
-
-
100/<60
-
-
-
-
-
O
3
E1190-X
2
80/0
5/4
60/0
100/0
-
100/0
5/0
20/<-20
5/~5
50/0
100/0
Cl
2
E1193-X
2
80/0
-
60/0
100/0
-
300/0
5/0
20/<-20
20/~20
50/0
100/0
H
2
E1194-A
-
10/0
-
100/80
-
50/200
5/0
25/0
5/0
35/<10
-
O
2
E1195-XX
2
-
-
-
-
-
-
-
-
-
-
-
SO
2
E1196-B
20/0
15/<1
-
50/<45
-
300/<1
-
25/<0.5
20/<-20
50/05
400/<1
H
2
S
E1197-A
50/0
15/0
-
100/0
5000/0
100/<2
20/0
-
5/<0.5
50/<0.5
-
H
2
S
E1197-B
50/0
15/0
-
100/0
5000/0
100/<2
20/0
-
5/<0.5
50/<0.5
-
H
2
S
E1197-C
50/0
15/0
-
100/0
5000/0
100/<2
20/0
-
5/<0.5
50/<0.5
-
H
2
S
E1197-D
50/0
15/0
-
100/0
5000/0
100/<2
20/0
-
5/<0.5
50/<0.5
-
H
2
S
E1197-E
-
-
-
-
-
100/<5
20/4
-
-
-
100/<5
ETO
E1199-A
-
-
30/21
-
-
100/~20
-
20/~40
-
-
-
1
The table does not claim to be complete. Other gases, too, can have an influence on the sensitivity. The mentioned cross
sensitivity data are only reference values valid for new sensors.
2
Cross sensitivity data valid for all measuring ranges of the sensor.

Table of Contents