16 Part Number 9294844 April 6, 2023
Installation Section 2
CONNECTIONS
See “System Pressures” on page 12 and “Regulator Settings &
Location” on page 13
1. Confirm correct orientation of Water and Air/CO
2
fittings.
2. The line set included with the unit should be equipped
with male quick connect fitting(s) for the water supply
line(s) and female quick connect fitting(s) for the Air/
CO2 supply line
Important
Leave enough slack in the water/CO
2
/drain lines to allow
access to the rear of the machine without disconnecting
the lines.
REGULATOR SETTINGS (During Flowing Conditions)
Pumps
Air / CO
2
35 psi
(0.24 MPa, 241 kPa, 2.41 bar)
CIP
Air / CO
2
70 psi
(.517 MPa, 517 kPa, 5.17 bar)
Plain Water
35 psi
(0.24 MPa, 241 kPa, 2.41 bar)
Chilled Water
35 psi
(0.24 MPa, 241 kPa, 2.41 bar)
Important
Regulators are factory set but will need to be checked
and possibly adjusted under flowing conditions once
the unit is operational.
See “How to Check Product Pumps Air/CO2 Pressure” on page
78 and “How to Check Plain Water Pressure” on page 79
3. Coil excess tubing and secure with tie straps.
Drain
See “Drain Connections” on page 14
4. Route drain line (minimum 1” ID) to drain, maintaining
a 2” (51 mm) air gap. Cut to proper length if needed (do
not leave loops in drain).
Electrical
See “Electrical” on page 11
5. If all electrical and grounding requirements have been
followed proceed to insert electrical plug from BIC into
wall receptacle.
6. Turn power and compressor switches, on the left-hand
side of the unit and the rear, to the ON position.
USB Port
Rear of UnitLeft Side of Unit
Power
Switch
Compressor
Switch
7. The touch screen should energize and inform the user to
perform Zone 2 & 3 cleaning before the unit can be put
into operation. See “Start-up & Cleaning” on page 17
Important
Do not add product to the machine until cleaning and
sanitizing are complete.