EasyManua.ls Logo

Multiplex WELBILT Blend-In-Cup MB-8-1PP6 - Checking Plain Water Pressure

Multiplex WELBILT Blend-In-Cup MB-8-1PP6
84 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Part Number 9294844 April 6, 2023 79
Section 5 Troubleshooting
How to Check Plain Water Pressure
1. Using the touch screen, gain access to the Blend
Chamber Rinse Button(s) located at the bottom of
either the Drink or Flavor Selection screen.
2. Activate a rinse cycle by touching the right or left rinse
button while reading the plain water regulator on the
rear of the unit.
3. The regulator will decrease to a stable pressure while
the water is flowing and then rise back to a higher
pressure once the rinse completes.
4. The Plain Water regulator should maintain 35 psi (241
kPa, 2.41 bar) +/- 2 psi (14 kPa, .14 bar) under flowing
conditions.
5. If the plain water regulator fails to maintain this
pressure during flowing conditions, call service to
adjust.
NOTE: * The Chilled Water Regulator needs to be a
minimum of 35 psi (241 kPa, 2.41 bar) at no flow conditions.
* Chilled Water
Gauge
Plain Water Gauge
Plain Water 35 psi
(241 kPa, 2.41 bar)
+/- 2 psi (14 kPa, .14 bar)
* Chilled Water 35 psi
(241 kPa, 2.41 bar)
+/- 2 psi (14 kPa, .14 bar)

Table of Contents

Related product manuals