Part Number 9294844 April 6, 2023 59
Section 4 Maintenance
Biannual Descaling - Zone 3
Descaling is recommended every six (6) months. More
frequent descaling may be required in some existing water
conditions. Follow carefully any instructions provided with
the bottles of Ice Machine Descaling or sanitizing solution.
n
Warning
Always wear liquid-proof gloves to prevent the descaling
and sanitizing solutions from coming into contact with
skin.
NOTE: All steps will be displayed on screen. * These items are
optional and may not be displayed on all easyToUCH screens
during ZONE 3 Cleaning.
Time to complete - 2 hours
Descaling must first be turned on in the Manager Menu
Service Screen before it can be performed as part of Zone 3
cleaning and will need to be turned off once completed.
Important
Only a trained manager or authorized technician
should access the service screens. If changes to these
settings are made incorrectly they can cause the unit to
malfunction or not work at all.
TURN ON DESCALING
1. Cycle touch screen to the Main Menu and select the
Managers Menu icon.
2. Enter the password using the QWERTY keyboard.
3. Press the down arrow to advance to the next screen.
4. Select the Service icon.
5. Enter the password using the QWERTY keyboard.
6. Select the CLEANING OPTIONS button.
2
3
6
5

Table of Contents