HARDWARE AND SPECIFICATIONS
MultiConnect
®
Dragonfly
TM
MTQ-MNG6-B02 Device Guide 13
Power Draw - MTQ-MNG6-B02
Multi-Tech Systems, Inc. recommends you incorporate a 10% buffer into your power source when determining
product load.
Note:
Maximum Power: The continuous current during maximum data rate with the radio transmitter at
maximum power.
Tx Pulse: The average peak current during a GSM850 transmission burst period or LTE connection. The
transmission burst duration for GSM850 can vary, depending on what transmission scheme is being
deployed (GPRS Class 8, Class 10, GSM, etc.).
Inrush Charge: The total inrush charge at power on.
Radio
Protocol
PSM
Mode
(CPSMS)
eDRX
Mode
eDRX
Mode
with
CFUN=5
Cellular
Connection
Idle (No
Data)
(Amps)
Average
Measured
Current at
Max Power
TX Pulse
(AVG)
Amplitude
Current for
Peak
Current for
LTE
Total Inrush
Charge
measured
Total Inrush
Charge
DURATION
during
Power up
3.3V with Device on the Developer Board
GSM 850
UDK Card
N/A N/A N/A 41 mA 290 mA 1.9 A 0.196 mC 1.38 mS
LTE BAND
12 UDK
Card
707.5Mhz
21 mA 40 mA N/A 53 mA 355 mA 896 mA 0.196 mC 1.38 mS
5V with Device on the Developer Board
GSM 850
UDK Card
N/A N/A N/A 40 mA 274 mA 1.78 A 0.254 mC 1.35 mS
LTE BAND
12 UDK
Card
707.5Mhz
21 mA 39 mA N/A 41 mA 350 mA 888 mA 0.254 mC 1.35 mS
5V with Device USB Only
GSM850
USB Only
N/A N/A N/A 40 mA 304 mA 1.79 A 0.10 mC 2.06 mS
LTE BAND
12 USB
Only
707.5Mhz
19 mA 44 mA N/A 43 mA 383mA 1.1 A 0.10 mC 2.06 mS