Cleaning
Cleaning recommendations
56 11.06.2014
¾ Attach the following components:
– Sealing bar, see Section 7.3.2 "INSTALL THE SEALING BAR".
– Filling plate.
– Sloping insert with with support angle.
¾ Install the chamber lid gasket.
¾ If necessary, dry the chamber lid gasket and groove with a new
cloth or sterile compressed air.
¾ Open the chamber lid as far as the limit stop and have a sec-
ond person hold it.
¾ Press the chamber lid gasket into the groove of the chamber
lid.
– The beginning and end of the chamber lid gasket must butt
up against each other without a gap.
¾ During insertion, do not stretch the chamber lid gasket.
¾ Smooth out chamber lid gasket.
¾ Leave the chamber lid open to dry.
¾ Check the chamber for leaks, see Section 7.9 "CHECK THE CHAM-
BER FOR LEAKS".
¾ If present, open the stop-cock for the gas supply.
¾ Connect the machine to the mains electricity.
¾ Clean the cleaning devices (e.g. rubber wipers, brushes).
¾ Place cleaning devices in disinfectant solution.
¾ Unpack the film pouches and lay them ready.
6.3 Care products table
Recommended care products:
Type Manufacturer Designation
Cleansers, neutral Ecolab Europa P3-topax 12