EasyManua.ls Logo

multivac P300 - Technical Specifications

multivac P300
90 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Description
Times which have to be set
11.06.2014 27
Time Explanation
Gas flushing
time (option)
The film pouch is filled with inert gas during this
time. The time depends on the input pressure at
the inert gas connection and on the vacuum level
reached in the chamber. If the gas flushing time is
too long, the chamber lid can open or the quality of
the seal seam can be impaired. The pressure dif-
ference becomes too small.
Recommended value: 1 s to 3 s
Sealing time The film pouch is sealed during this time. The seal-
ing time depends on the material and thickness of
the film pouch.
Recommended value: 1.5 s to 1.7 s
2.7 Technical specifications
Power supply
Mains voltage 220 V - 240 V/50Hz -
60 Hz
100 V - 115 V/50Hz -
60 Hz
Phases 1/N/PE AC
Nominal power 0.9 kW
Nominal current 5.6 A 12.5 A
Maximum mains fuse 16 A 20 A
Maximum short cir-
cuit current
5 kA
Protection type IP54
Dimensions
Height (a) with open chamber lid 745 mm
Height (a) with completely open
chamber lid
910 mm
Height (a) with closed chamber
lid
400 mm
Width (b) 520 mm
Depth (c) 640 mm
Operating height approx. 315 mm
Effective chamber size (W/H/D) 420 mm/170 mm/425 mm
Sealing length 420 mm

Table of Contents