Troubleshooting
11.06.2014 77
8 Troubleshooting
WARNING
Injury hazard!
Ignorance of proper machine handling is very dangerous.
Improper handling can lead to serious injuries.
For all service and repair work:
¾ Make sure you observe the safety instructions and accident
prevention regulations.
¾ Disconnect the unit's power supply from the mains electricity.
¾ Only qualified electricians are permitted to work on electrical
modules.
¾ Service and repair work should be carried out by authorised
technicians only.
8.1 Faults with diagnostic message
Error Symptom Cause Solution
Gas strut is un-
hooked.
Hook in the gas strut,
for this open the
chamber lid more
than half way.
• Ventilation valve
does not open.
Notify the service.
E0 The chamber lid does
not open after the
packaging procedure.
Machine control is
defective.
Notify the service.
E1 Chamber lid opens
during the sealing
process.
The pressure dif-
ference between
the chamber and
the outside envi-
ronment is not
large enough be-
fore the sealing
process.
Set the evacuation
time and gas flushing
time such that the
pressure display
shows a pressure dif-
ference of at least
0.35 bar before the
sealing process.
8.2 Faults without diagnostic message
Symptom Cause Solution
Machine is switched off. Switch on the machine. Machine does not run.
Mains plug is unplugged. Plug in the mains plug.