Transport, storage and disposal
4.2 Preservation
No preservation required.
Do not preserve the pump.
4.3 Storage
CAUTION
Material damage due to inappropriate storage!
Store the pump appropriately.
1. Seal all openings with blind flanges, blind plugs or plastic
covers.
2. For models with oil-lubricated bearings and downtimes in
excess of one year:
– Dismount any existing reservoir
– Dismount any existing oil level controller
– Seal the tap hole
– Fill the bearing bracket with oil, up to the brim
– Seal the bleeding hole
3. Make certain that the storage room meets the following
conditions:
–dry
– frost-free
– vibration-free
4. Turn shaft once a month.
5. Make certain that the shaft and the bearing change their
rotational position in the process.
4.4 Disposal
Plastic parts can be contaminated by poisonous or radio-
activepumpedmediatosuchanextentthatcleaningwill
be insufficient.
WARNING
Risk of poisoning and environmental damage caused by
pumped medium or oil!
Use protective equipment when carrying out any work on
the pump.
Prior to disposal of the pump:
– Collect pumped medium and oil or grease running out
and dispose of the pumped medium according to local
regulations.
– Neutralize residues of pumped medium in the pump.
Dismount plastic parts and dispose of the parts accord ing
to local regulations.
Dispose of pump according to local regulations.
14 NPC series BA-2005.07 EN – 02