EasyManua.ls Logo

Munsch NPC Series - Tab. 13 Troubleshooting List

Munsch NPC Series
45 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Disturbance recovery
Fault number
12 34
5
6
7
89
Cause
Remedy
–– ––
X
––
Lubricant: too much, too little or unsuitable
Reduce, top up or replace lubricant.
–– –––
X
Connecting screw or bolts not tightened
correctly
Tighten connecting screws and bolts.
–– –––
X
Stationary seal ring worn
Replace stationary seal ring.
–– –––
X
Casing seal defective
Replace casing seal.
–– –––
X
Shaft sleeve is infiltrated
Replace shaft sleeve and/or O-rings.
––
XXXXPumpdistorted
Check pipe connections and pump
fixation.
Check coupling alignment.
Check support foot fixation.
––
XX
––
Coupling not properly aligned
Align coupling.
––
X
––
Coupling packets worn
Replace coupling packets and realign.
X
X
X
––
X Motor running on 2 phases
Check fuse and replace it if necessary.
Check cable connections and
insulation.
Tab. 13 Troubleshooting list
EN 02 BA-2005.07 NPC series 33