13
heatless desiccant air dryer
D3
4.3 shutdown procedure - standard controller
Isolate unit from compressed air system.
The unit will still be pressurized
Ensure the unit is fully depressurized and isolated
To fully depressurize, following the steps below;
Cycle the dryer at least twice to ensure the unit exhausts and is completely depressurized.
When fully depressurized the ‘clicking’ of the exhaust valves will be heard but no air exhausted.
When the unit is fully depressurized, isolate from the electrical supply.