MICROSOFT WORD 2002 89-22091 / VERSION 1 / 13.03 2007
Functional description for control unit ED520
Function
number
Function Setting K0 k1 k2 k3 k4 k5 k6 k7
a UP function
1
b
Pull switch function
Toggle function X
X X X X X X
a
Up – Stop – Up – Stop … X
X X X
2
b
Pull switch toggle function
Up – Stop – Down – Stop – Up …
X X X
a UP function outside
3
b
Extra input
Automatic closing ON/OFF X
X X X X X X
a With automatic closing
X X X X X
4
b
Automatic closing
Without automatic closing X
X
a With carwash function
X X X
5
b
Carwash function at automatic
closing
Without carwash function X
X X X
a With forced closing
X
6
b
Forced closing at carwash
function
Without forced closing X
X X X X X
a
Inside X
X X X X X X
7
b
Radio/Pull
Outside
a Show value for programmable height
8
b
Programmable opening height
X
X X X X X X
a With step at bottom position
9
b
Step at bottom position
Without step a bottom position X
X X X X X X X
a Choose factory settings
10
b
Basic setting
X
X X X X X X X
a Viewing cycle counter value
11
b
Cycle counter
X
X X X X X X X
a Viewing the 2 latest failure
12
b
Latest failure
X
X X X X X X X
a Run-in sequence
13
b
Run-in
X
X X X X X X X
a Motor stop limit adjustment
14
b
Motor stop limit
X
X X X X X X X
a
Automatic mode X
X X X X X X
15
b
Mode
Normal hold to run mode
X
a Set safety functions
SF
b
Safety functions
X
X X X X X X X
a Finish comfort settings
EC
b
Finish
X
X X X X X X X
7 ED520 Indications
The status at each input by normal operation can be read by means of the table below.
By pressing SW1 or SW2 the input status indication will appear. Next input is selected by pressing SW1 and
previous input by pressing SW2.
The input status indication will automatically terminate 20 seconds after activating the buttons.
If the buttons are activated again within 60 seconds after the indication mode was terminated, the input
number selection will resume where it was left. If not, the first input will be selected.