Chapter 5 Analog Output
X Series User Manual 5-6 ni.com
Figure 5-2. Analog Output Connections
Analog Output Timing Signals
Figure 5-3 summarizes all of the timing options provided by the analog
output timing engine.
Figure 5-3. Analog Output Timing Options
X Series devices feature the following analog output (waveform
generation) timing signals:
AO Start Trigger Signal
*
AO Pause Trigger Signal
*
Load
Load
V OUT
V OUT
+
+
AO GND
AO 3
Analog Output Channels
AO 2
Channel 3
Connector 1 (AI 16 31)
Channel 2
X Series Device
Load
Load
V OUT
V OUT
+
+
AO GND
AO 1
Analog Output Channels
X Series Device
AO 0
Channel 1
Channel 0
Connector 0 (AI 0 –15)
PFI, RTSI
PXI_STA R
Analog Comparison
Event
20 MHz Timebase
100 kHz Timebase
PXI_CLK10
Programmable
Clock
Divider
AO Sample Clock
Timebase
PFI, RTSI
PXI_STA R
Analog Comparison Event
Ctr n Internal Output
100 MHz Timebase
DSTAR <A..B>
DSTAR <A..B>
AO Sample Clock