Chapter 3 Analog Output
© National Instruments Corporation 3-15 E Series User Manual
Figure 3-12 shows the timing requirements for MasterTimebase.
Figure 3-12. MasterTimebase Timing Requirements
Getting Started with AO Applications in Software
You can use the E Series device in the following analog output
applications:
Single-Point Generation
Finite Generation
Continuous Generation
Waveform Generation
You can perform these generations through DMA, interrupt, or
programmed I/O data transfer mechanisms. Some of the applications also
use start triggers and pause triggers.
Note For more information about programming analog output applications and triggers in
software, refer to the NI-DAQmx Help or the LabVIEW 8.x Help.
t
p
= 50 ns minimum
t
w
= 23 ns minimum
t
w
t
w
t
p