EasyManua.ls Logo

National Instruments PCI E Series - Page 79

National Instruments PCI E Series
162 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 4 Programming
PCI E Series RLPM 4-16
©
National Instruments Corporation
7. Convert_Signal selects the convert signal for the acquisition.
Joint_Reset_Register
AI configuration start = 1;
AI_SI2_Load_A_Register
AI SI2 special ticks -1 = 1999;
AI_SI2_Load_B_Register
AI SI2 ordinary ticks -1 = 1999;
AI_Mode_2_Register
AI SI2 reload mode = 1;
AI_Command_1_Register
AI SI2 load = 1;
AI_Mode_2_Register
AI SI2 initial load source = 1;
Joint_Reset_Register
AI configuration start = 0;
AI configuration end = 1;
8. Perform Analog Input Example 1 Step 4.
9. The function
AI_Interrupt_Enable enables interrupts for the
acquisition.
Interrupt_A_Enable_Register
AI FIFO interrupt enable = 1;
AI error interrupt enable = 1;
Interrupt_Control_Register
MSC IRQ pin = 0;
MSC IRQ enable = 1;
10. Call
AI_Arming to arm the analog input counter.
AI_Command_1_Register
AI SC arm = 1;
AI SI arm = 1;
AI SI2 arm = 1;
AI DIV arm = 1;
11. Install the interrupt service routine to handle the interrupt.
Interrupt_Service_Routine()
read FIFO data;
increment sample counter;

Table of Contents