Chapter 4 Programming
©
National Instruments Corporation 4-21 PCI E Series RLPM
transfers finish, call MITE_DMAdisarm twice for DMA channel 0 and
channel 1.
Example 5
Example 5 performs the same acquisition as Example 2, but with the start
trigger and scan start pulses applied externally.
Acquire 5 scans. The scan list contains channels 5, 4, 1, and 0, respectively,
each at a gain of 1 and in RSE mode. The acquisition should begin on a start
trigger applied to PFI0. The sample rate should be set to 100 µs, and the
start pulses should be connected to PFI1 to trigger each scan. Use polled
input to read the AI FIFO data.
1. Perform Analog Input Example 1 Step 1.
2. Perform Analog Input Example 1 Step 2 for each channel in the scan
list. Only channel 0 has Last channel set to 1.
3. Perform Analog Input Example 1 Steps 3 through 8.
4. Call
AI_Trigger_Signals to set the triggering options.
Joint_Reset_Register
AI configuration start = 1;
AI_Mode_1_Register
AI trigger once = 1;
AI_Trigger_Select_Register = 0x8061;
Joint_Reset_Register
AI configuration start = 0;
AI configuration end = 1;
5. Call the function
Number_of_Scans to load the number of scans.
Joint_Reset_Register
AI configuration start = 1;
AI_SC_Load_A_Registers (24 bits)
Number of posttrigger scans -1 = 4;
AI_Command_1_Register
AI SC Load = 1;
Joint_Reset_Register
AI configuration start = 0;
AI configuration end = 1;
6. The function
AI_Scan_Start selects the scan start event.
Joint_Reset_Register
AI configuration start = 1;