Chapter 2 Installation and Configuration
© National Instruments 2-3 NI PXI-8109 User Manual
7. Raise the injector/ejector handle until the module firmly seats 
into the backplane receptacle connectors. The front panel of the 
NI PXI-8109 should be even with the front panel of the chassis.
8. Tighten the four bracket-retaining screws on the top and bottom of the 
front panel to secure the NI PXI-8109 to the chassis.
9. Check the installation.
10. Connect the keyboard and mouse to the appropriate connectors. If you 
are using a PS/2 keyboard and a PS/2 mouse, a Y-splitter adapter is 
available to connect both to a single USB connector. Refer to 
Figure 4-1, Y-Splitter Cable.
11. Connect the DVI monitor video cable to the DVI connector, or use the 
DVI-to-VGA adapter included with your controller to connect a VGA 
monitor to the DVI connector. Connect devices to ports as required by 
your system configuration.
12. Power on the display device.
13. Power on the chassis.
14. Verify that the controller boots. If the controller does not boot, refer 
to the What if the NI PXI-8109 does not boot? section of Chapter 5, 
Troubleshooting.