Appendix A Specifications
NI PXI-8109 User Manual A-2 ni.com
Electrical
Physical
Board dimensions ...................................PXI 3U-size module
8.1 cm × 13 cm × 21.6 cm
(3.2 in. × 5.1 in. × 8.5 in.)
Slot requirements....................................One system slot plus
three controller expansion slots
Compatibility ..........................................Fully compatible with
PXI specification
Weight ....................................................1.30 kg (2.87 lb) typical
Environment
Maximum altitude...................................2,000 m (800 mbar)
(at 25 °C ambient temperature)
Pollution Degree .....................................2
Indoor use only.
Voltage (V)
Current (A)
Typical Maximum
+3.3 2 A 3 A
+5 (+5 V
DC
and +5 V
IO
)
*
8 A 9.5 A
+12 .050 A .150 A
–12 0 A 0 A
* Does not include any attached USB devices or ExpressCard.