Appendix A Specifications
NI PXI-8109 User Manual A-4 ni.com
Shock and Vibration
Operational shock ...................................30 g peak, half-sine, 11 ms pulse 
(Tested in accordance with 
IEC-60068-2-27. Test profile 
developed in accordance with 
MIL-PRF-28800F.)
Random vibration
Operating .........................................5 to 500 Hz, 0.3 g
rms
 
(with solid-state hard drive)
Nonoperating ...................................5 to 500 Hz, 2.4 g
rms 
(Tested in accordance with 
IEC-60068-2-64. Nonoperating 
test profile exceeds the 
requirements of 
MIL-PRF-28800F, Class 3.)
Note Specifications are subject to change without notice.
Safety
This product is designed to meet the requirements of the following 
standards of safety for electrical equipment for measurement, control, 
and laboratory use:
• IEC 61010-1, EN 61010-1
• UL 61010-1, CSA 61010-1
Note For UL and other safety certifications, refer to the product label or the Online 
Product Certification section.
Electromagnetic Compatibility
This product meets the requirements of the following EMC standards for 
electrical equipment for measurement, control, and laboratory use:
• EN 61326-1 (IEC 61326-1): Class A emissions; Basic immunity
• EN 55011 (CISPR 11): Group 1, Class A emissions
• AS/NZS CISPR 11: Group 1, Class A emissions
• FCC 47 CFR Part 15B: Class A emissions
• ICES-001: Class A emissions