EasyManua.ls Logo

NEC Express5800 Series - Page 190

NEC Express5800 Series
238 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1. IML Error Message
Express5800/R120h-1E, R120h-2E Maintenance Guide
190
Chapter 3 Appendix
Class
Error
code
Error message Action
UEFI 343
IMPORTANT: NVDIMM backup power has
been lost and a future backup is not
possible. Data from the last successful
backup is intact, but data modified after the
last successful backup will be lost if power
cannot be restored.
Check the backup power supply of the NVDIMM. Back
up the contents recorded in the NVDIMM to other media
to protect the data. If the problem persists, contact your
sales representative.
UEFI 344
NVDIMM Error - NVDIMM Controller Error -
Processor %1, DIMM %2
(SN:%3-%4-%5-%6). An error was found
with the NVDIMM controller. The OS will
not use the NVDIMM. Data from last
successful backup is still available, but will
be lost if controller error persists.
Please take actions in the following order.
1. Back up the contents recorded in the NVDIMM to
other media to protect the data.
2. Contact your sales representative.
UEFI 345
NVDIMM Error - Erase Error -
Processor %1, DIMM %2
(SN:%3-%4-%5-%6). NVDIMM could not
be erased by the NVDIMM controller FW
and future backups are not possible.
Please take actions in the following order.
1. Back up the contents recorded in the NVDIMM to
other media to protect the data.
2. Contact your sales representative.
UEFI 346
NVDIMM Error - Arming Error -
Processor %1, DIMM %2
(SN:%3-%4-%5-%6). NVDIMM could not
be armed and future backups are not
possible.
Please take actions in the following order.
1. Back up the contents recorded in the NVDIMM to
other media to protect the data.
2. Contact your sales representative.
UEFI 351
IMPORTANT: %1 is not charged sufficiently
to support the energy-backed persistent
memory installed in the system. The
system will wait for the battery to charge
sufficiently before continuing boot.
Perform one of the following actions.
1. Wait until the battery is fully charged so that the unit
can continue to be operated.
2. Press the <ESC> key to continue operating without
waiting for the battery fully charged.
UEFI 352
IMPORTANT: %1 is not charged sufficiently
to support the energy-backed persistent
memory installed in the system. System
configured to not wait for battery to charge.
Persistent memory regions may not be
available in the OS.
Perform one of the following actions.
1. Wait until the battery is fully charged so that the unit
can continue to be operated.
2. Change to the setting where the unit operation is
suspended until the battery is fully charged.
UEFI 353
IMPORTANT: Possible Password
Corruption. The PW authentication
algorithm detected an issue which has
been corrected.
Reset your password. To clear the currently set
password, follow the procedure in Chapter 1 (7.
Resetting and Clearing the Server) in this manual.
If the problem persists, contact your sales
representative.
UEFI 354
Unsupported NVDIMM-N Configuration
Detected - Processor %1 DIMM %2. The
installed NVDIMM-N is not supported.
A connection of unavailable NVDIMM-N has been
detected. Check the installation of the NVDIMM - N. If
the problem persists, contact your sales representative.

Table of Contents

Other manuals for NEC Express5800 Series

Related product manuals