1. IML Error Message
Express5800/R120h-1E, R120h-2E Maintenance Guide
192
Chapter 3 Appendix
Class
Error
code
Error message Action
UEFI 372
IMPORTANT: Processor %1, DIMM %2.
New NVDIMM detected and has been
disabled.
Sanitize the NVDIMM connected to the corresponding
processor. If the problem persists, contact your sales
representative.
UEFI 373
IMPORTANT: NVDIMM(s) have been
removed from Processor %1. All NVDIMMs
on Processor %2 have been disabled.
Please take actions in following order.
1. Sanitize the NVDIMM connected to the
corresponding processor.
2. If the problem persists, contact your sales
representative.
UEFI 374
NVDIMM Error - Processor %1, DIMM %2
(SN:%3-%4-%5-%6) received a memory
initialization or uncorrectable error. All
NVDIMMs on Proc %7 are disabled. Data
on NVDIMM may have been lost
Please take actions in following order.
1. Sanitize the NVDIMM.
2. Contact your sales representative.
UEFI 375
NVDIMM Error - Processor %1, DIMM %2
(SN:%3-%4-%5-%6) received a memory
initialization or uncorrectable error.
NVDIMM has been disabled. Data on
NVDIMM may have been lost.
Please take actions in following order.
1. Sanitize the NVDIMM.
2. Contact your sales representative.
UEFI 376
NVDIMM Error - Processor %1, DIMM %2.
NVDIMM set for interleaving disabled but
system configured for interleaving enabled.
All NVDIMMs on Processor %3 are
disabled.
Set NVDIMM Interleaving to Disabled, or sanitize the
NVDIMM. If the problem persists, contact your sales
representative.
UEFI 377
NVDIMM Error - Processor %1, DIMM %2.
NVDIMM set for interleaving enabled but
system configured for interleaving
disabled. NVDIMM has been disabled.
Set NVDIMM Interleaving to Enabled, or sanitize the
NVDIMM. If the problem persists, contact your sales
representative.
UEFI 378
NVDIMM Error - Processor %1, DIMM %2.
NVDIMM is configured for a different
processor type. All NVDIMMs on
Processor %3 are disabled.
Sanitize the NVDIMM. If the problem persists, contact
your sales representative.
UEFI 379
NVDIMM Error - Processor %1, DIMM %2.
NVDIMM is configured for a different
processor type. NVDIMM has been
disabled.
Sanitize the NVDIMM. If the problem persists, contact
your sales representative.
UEFI 380
NVDIMM Error - Processor %1, DIMM %2.
NVDIMM location changed. All NVDIMMs
on Processor %3 are disabled.
Install the NVDIMM in the corresponding DIMM slot, or
sanitize the NVDIMM. If the problem persists, contact
your sales representative.
UEFI 381
NVDIMM Error - Processor %1, DIMM %2.
NVDIMM location changed. NVDIMM has
been disabled.
Install the NVDIMM in the corresponding DIMM slot, or
sanitize the NVDIMM. If the problem persists, contact
your sales representative.