1. IML Error Message
Express5800/R120h-1E, R120h-2E Maintenance Guide
194
Chapter 3 Appendix
Class
Error
code
Error message Action
UEFI 394
NVDIMM Error - Processor %1, DIMM %2
(SN:%3-%4-%5-%6). Unable to set event
notification for this NVDIMM to generate
alerts for health changes, including a loss
of data persistency.
Updating the system ROM and the innovation engine
firmware may solve the error. Please update the system
ROM and the innovation engine firmware.
If the problem persists, contact your sales
representative.
UEFI 395
NVDIMM Error - Processor %1, DIMM %2
(SN:%3-%4-%5-%6). NVDIMM
Persistency is lost and future data backup
is not available.
Please take actions in following order.
1. Back up the contents recorded in the NVDIMM to
other media to protect the data.
2. Contact your sales representative.
UEFI 396
IMPORTANT: Processor %1, DIMM %2 -
NVDIMM Persistency is restored and
future data backup is available.
Action is not necessary.
UEFI 397
WARNING: Processor %1, DIMM %2
(SN:%3-%4-%5-%6). NVDIMM lifetime has
been reached.
Please take actions in following order.
1. Back up the contents recorded in the NVDIMM to
other media to protect the data.
2. Contact your sales representative.
UEFI 398
NVDIMM Configuration Error -
Processor %1, DIMM %2
(SN:%3-%4-%5-%6). Backup power is not
available to this DIMM slot. NVDIMM is
disabled.
Install the NVDIMM in the slot where the NVDIMM is
available. If the problem persists, contact your sales
representative.
UEFI 399
INFORMATION: Processor %1, DIMM %2
(SN:%3-%4-%5-%6). Extended Diagnostic
Information (Data1 = 0x%7, Data2 = 0x%8,
Data3 = 0x%9, Data4 = 0x%10).
Action is not necessary.
However, if the error is recorded repeatedly, please
contact your sales representative.
UEFI 400
Intrusion Alert Detection - The server
chassis hood is currently not installed.
An intrusion warning has been detected. The cover of
the server has not been installed. Check the installation
of the cover.
If the problem persists, contact your sales
representative.
UEFI 401
Intrusion Alert Detection - The server
chassis hood was removed prior to this
power on.
An intrusion warning has been detected. It detected that
the server cover has been once removed. Check the
status of the server.
If the problem persists, contact your sales
representative.
UEFI 402
Intrusion Alert Detection - The required
intrusion detection cable is missing.
An intrusion warning has been detected. The intrusion
detection cable is not connected. Check the status of
the server.
If the problem persists, contact your sales
representative.
UEFI 403
Intrusion Alert Configuration Error -
Intrusion Alert Detection cable is installed
but the feature is not enabled.
An intrusion warning has been detected. While the
intrusion detection cable has been connected, its
function is not enabled. Check the settings of the server.
If the problem persists, contact your sales
representative.
UEFI 410
Innovation Engine Error - The Innovation
Engine is not operating properly. (Error
Code %1).
Updating the system ROM and the innovation engine
firmware may solve the error. Please update the system
ROM and the innovation engine firmware.
If the problem persists, contact your sales
representative.