1. IML Error Message
Express5800/R120h-1E, R120h-2E Maintenance Guide
204
Chapter 3 Appendix
Class
Error
code
Error message Action
UEFI 2404
Slot %1 SAN Error - Adapter restart failed.
Firmware not ready. Boot from SAN not
possible.
Reconnect SAN ports or restart the server. If the
problem persists, contact your sales representative.
UEFI 2405
Slot %1 Error - Vital Product Data (VPD) is
not available.
Update the firmware of the card in slot %1. If the
problem persists, contact your sales representative.
UEFI 2406
Slot %1 NIC Error - NIC personality
(Ethernet, iSCSI, or FCoE) could not be
changed. FW may require update.
Update the firmware of the NIC card in slot %1 before
restarting the server.
UEFI 2407
Slot %1 Error - The firmware update did not
complete successfully.
Update the firmware of the card again after confirming
the firmware image of the card in slot %1 is correct.
UEFI 2408
Slot %1 Error - Firmware image recovery
not successful.
Restart the unit. If the problem persists, contact your
sales representative.
UEFI 2409
Slot %1 Error - Failure to apply Virtual
Connect (VC) settings.
Confirm the VC configuration. Apply the VC
configuration again after restarting the server.
UEFI 2410
Slot %1 Error - Controller I/O timeout
failure.
Restart the unit. If the problem persists, contact your
sales representative.
UEFI 2411
%1: iSCSI Error - Failed to acquire DHCP
client network address.
Check the network cables and the DHCP server
configuration. Restart the server.
UEFI 2412
%1: iSCSI Error - Failed to acquire DHCP
target network address.
Check the network cables and the DHCP server
configuration. Restart the server.
UEFI 2413
%1: iSCSI Error - Failed to acquire DHCP
iSNS Server IP address.
Check the network cables, the DHCP server
configuration and the iSNS server configuration. Restart
the server.
UEFI 2414 %1: iSCSI Error - iSCSI login failed.
Confirm and set the cable connection, the controller
configuration, and the configurations of iSCSI initiator
and the target properly. Then restart the server.
UEFI 2415 %1: iSCSI Error - Boot LUN not available.
Confirm and set the controller configuration and the
iSCSI server configuration properly. Then restart the
server.
UEFI 2416 %1: Error - Controller firmware not ready.
Restart the unit. If the problem continues, update FW. If
the problem persists, contact your sales representative.
UEFI 2419
%1 %2 Error - Rx/Tx is disabled on this
device because an unsupported SFP+ or
QSFP module type was detected.
Contact your sales representative.
UEFI 2420
%1 %2 Error - The UEFI driver for the
device detected an older version of the
NVM image than expected.
Update the NVM image. If the problem persists, contact
your sales representative.
UEFI 2421
%1 %2 Error - The UEFI driver for the
device detected a newer version of the
NVM image than expected.
Update the NVM UEFI driver to the latest version. If the
problem persists, contact your sales representative.
UEFI 2422
%1 %2 Error - The UEFI driver for the
device stopped because the NVM image is
newer than expected.
Update the NVM UEFI driver to the latest version. If the
problem persists, contact your sales representative.
UEFI 3100
Trusted Platform Module (TPM) was
successfully bound to system.
Action is not necessary. The unit restarts automatically.