Chapter 2 System Configuration Mounting IP-PAD Card
NEAX 2000 IPS Configuration Guide
NDA-24347, Issue 1
Page 17
Maintenance Conditions for Maintenance
• MATWorX can be used as the maintenance program for NEAX 2000 IPS. Direct
connection (RS-232C), Modem connection and LAN (TCP/IP) connection are
available to connect to the Maintenance Administration Terminal (MAT).
• When using the MATWorX Version 3 or later, the message (OK) for completion
of system data memory all clear is not displayed on the MOC window.
• You can check the condition of LAN cable connection by transmitting the PING
packet to the ETHER card from PC on the LAN.
IP-PAD/VCT Card Cautions for Unplugging/Plugging IP-PAD/VCT Card
• The IP-PAD card must be plugged in or unplugged under Make Busy condition or
power off to prevent damages from occurring to the card or other system circuitry.
• Turn ON the MB switch on the IP-PAD card before the following operations:
• Resetting the MP (MP built-in FP)/FP card controlling the IP-PAD cards
• Inserting or extracting the VCT cards during on-line
• Plugging or unplugging the BUS cable (IPT TRK BUS CA) between the IP-
PAD and VCT cards
• After the above operations, turn OFF the MB switch.
• Be sure to insert all of the VCT cards firmly into their slots, which are connected
to the IP-PAD card by the BUS cable. Otherwise, the IP-PAD card connected to
the VCT card will not operate normally.
Mounting IP-PAD Card
1. Before mounting the IP-PAD (PN-32IPLA) card, set the MB switch to UP
position, and set the other switches to their correct positions.
2. Mount the IP-PAD card in one of the following LT slots of PIM 0 - PIM 7.
Maximum of two IP-PAD cards per MP built-in FP/FP, maximum of eight per
system can be mounted.
• LT00, LT01 in PIM 0/2/4/6: Card Number 0
• LT04, LT05 in PIM 0/2/4/6: Card Number 1
• LT00, LT01 in PIM 1/3/5/7: Card Number 2
• LT04, LT05 in PIM 1/3/5/7: Card Number 3
Note 1: One IP-PAD card requires two physical slots and two vacant slots.
Note 2: Do not mount any other L/T cards in the LT08-LT11 slots when you mount the