Line/Trunk (LT) Cards
Table 4-3 shows a summary of the Line/Trunk (LT) cards for NEAX 2000 IPS. The LT cards may be installed in
Slot 00 to 11 of PIM 0-7, with the following conditions:
Maximum 64 ports per PIM
Table 4-3 Line/Trunk (LT) Cards
ABBR. NAME CODE
PART
NUMBER
PORT REMARKS
IP PAD
SPN-32IPLA IP PAD
SC-3013 IXS IP PAD PROG-A1
151227 32
IP Interface Card
•For IP PAD
Maximum of two without FP system
Maximum of two per FP system
Maximum of eight per system
SPN-16VCTA IP PAD
IP-TRK BUS CA
SP-3636 VCTA VC PROG-A
151226 0
16-channel CODEC Card
•For IP PAD
Maximum of two per 32IPLA card
Minimum of one 16VCT is required per
32IPLA.
LC
PN-8LCAA 150114 8
8-line Analog Line Circuit
Message Waiting Control: Eight circuits
Momentary Open: Eight circuits
Loop Resistance: Maximum 600
including telephone set
PN-4LCD-A 150216 4
4-line Analog Line Circuit
Message Waiting Lamp Control
Momentary Open: One circuit
Loop Resistance: Maximum 600
including telephone set
PN-4LLCB 151220 4
4-line Long Line Circuit
Works in either mode:
Long Line Station
Caller ID
Loop Resistance: Maximum 2,500
including telephone set
PZ-PW122 is required.