© by NECTA VENDING SOLUTIONS SpA
20
0301 162-00
DIRECT FUNCTIONS
RESETTING FAILURES
When pressing the failure reset button “4” the message
"Working" is displayed for a few seconds and all present
failures will be reset.
INSTALLATION
Pressing the installation button “5” will enable the filling
operation of the hydraulic system, even with the air break
full.
RESETTING THE STATISTICS
Press the statistics reset button “6” and the message
"Confirm?" is displayed blinking.
Press the confirm button “2” and the message "Working" is
displayed for a few seconds and the statistics are reset.
PRINTING THE STATISTICS
The statistics described in the section "displaying the
statistics" can be printed with a RS-232 serial printer with
a Baud rate of 9600, 8 data bit, no parity, 1 stop bit,
connected to the serial port located on the push button
board . The hardcopy printout will also contain the machine
code number and the printout progressive number.
The progressive hardcopy printout number can be reset
only by initializing the machine.
To connect the printer do as follows:
- Press the statistics print button “7” to display the message
"Confirm?";
- before confirming connect the printer;
- press the confirm button “2” to start printing.
DISPLAYING THE STATISTICS
Press the statistics display button "8" to display in a
sequence at 1 second intervals the stored data, if no other
buttons are pressed, and namely:
1 - MDB statistics
Aud. 1 Money in the tubes
Money present that moment in the change-giver tubes.
Aud. 2 Money to the tubes
Money sent to the change-giver tubes.
Aud. 3 Money to the box
Money sent to the coin-box.
Aud. 4 Change return
Total returned money.
Aud. 5 Excess
Excess money. Extra amounts paid by the customer,
which were not returned (in the even there is no money
available for change).
Aud. 6 Releasing tubes
Value of coins dispensed by means of the "Tube control"
function.
Aud. 7 Filling tubes
Value of coins cashed by means of the manual filling
function.
Aud. 8 Cash sales
Value of total sales by means of cash (coins + bills).
Aud. 9 Cashed bills
Value of cashed bills.
Aud.10 Charging key
Value of money charged to the key.
Aud.11 Sales with key
Value of money cashed by means of selections with a key.
Aud.12 Money dispensed manually
Value of coins dispensed manually by means of the
dispensed buttons on the coin mechanism.
2- single selection counter
3 - failure counter
4 - single price counter
normal
discounted