EasyManua.ls Logo

Nedap NVITE - 3.3 Inputs

Nedap NVITE
40 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
NVITE | installation guide
13/
40
3.3 Inputs
The NVITE reader has 3 digital inputs (active low).
Connect to ground to active the input. Leave unconnected otherwise.
Connections
RED/BLUE
Input 0 - LED_UL_IN (active-low)
WHITE
Input 1 - LED_NA_IN (active-low)
BLUE
Input 2 - BEEP_IN (active-low)
BLACK
Ground
SHIELD
Shield connected to DC-ground
STANDARD firmware
The digital inputs can be used to control the LED and buzzer. See details about LED/buzzer control in chapter 4.3.2.
OSDP firmware
The digital inputs are general purpose inputs.
Upon status change the reader will send input status report message OSDP_ISTATR.
The current input status can be requested by sending the input status report request message OSDP_ISTAT.

Other manuals for Nedap NVITE

Related product manuals